Neuromuscular electrical stimulation therapy, also known as low-frequency pulse electrical therapy or electrical exercise therapy, is a method of applying low-frequency pulse current to damaged nerves and muscles, causing passive contraction and promoting muscle movement and nerve regeneration for treatment purposes.
The QL/N series neuromuscular electrical stimulation instrument massage machine is used to treat limb diseases caused by partial nerve loss, complete nerve loss, and peripheral nerve damage. It is mainly used for electric stimulation of the muscles that are partially denervated after nerve damage, protecting and treating the denervated muscles, and shortening the recovery period of muscle movement function.
Advanced human-machine interaction system, 7-inch large color LCD display, Chinese menu, and electronic instruction manual.
The treatment waveform, treatment dosage, treatment prescription, and treatment time of each channel can be displayed, and the treatment data is clear at a glance.
Unique intelligent control system, which can quickly select parameters and operations.
Treatment prescription can be selected.
The intensity of each current can be adjusted independently.
Automatic termination reminder and reset function. After the treatment is over, the massage machine will sound an alert to indicate the end of the treatment, and the current output will automatically stop.
Pulse waveform
Pulse waveform is a double-sided asymmetrical square wave (rectangular wave), and the modulation waveform is a square wave.
Output frequency
Mode 1 (Ⅰ gear) output pulse fundamental frequency is 500Hz; modulation pulse frequency is 0.5Hz to 5Hz; mode II (Ⅱ gear) output pulse frequency is 0.5Hz to 5Hz.
Pulse width and modulation wave pulse width
Mode 1 (Ⅰ gear) output pulse width is 1ms; modulation wave pulse width is 10ms; mode II (Ⅱ gear) output pulse width is 10ms.
Output intensity
The massage machine independently outputs each channel, and the peak value Ip of each channel output current can be continuously adjusted from 0mA to 100mA under a load impedance of 1KΩ.
The product is used to treat diseases caused by complete nerve loss or partial nerve loss.
After the peripheral nerves are damaged for various reasons, the function of the muscles innervated by nerves will weaken or disappear. After losing nerve support, the muscles will undergo a series of adverse changes, such as muscle atrophy, degeneration of the neuro-muscular junction, changes in membrane potential, decreased muscle tone, slow contraction response, weakened or disappeared reflex, etc. During this period, active and effective protection measures should be taken to the muscles to prevent atrophy and degeneration, maintain normal muscle function, and improve muscle tone. Once nerve support function is restored, the patient's movement function can also quickly recover.